ION SELECTIVE ELECTRODES

Combination ion selective electrodes for the direct determination of Fluoride, Chloride, Cyanide, Bromide and Iodide Ions. Featuring Ionode's unique Intermediate Junction Reference for accuracy and fast response time.

 
 

Model Parameter Measuring Range Detection Limit Slope
IJ-Cl
Cl-
1.8 - 35000 ppm
0.4 ppm
57mV/decade ± 5mV
IJ-Br
Br-
0.8 - 80000 ppm
0.08 ppm
57mV/decade ± 5mV
IJ-I
I-
0.13 - 130000 ppm
0.006 ppm
57mV/decade ± 5mV
IJ-CN
CN-
0.05 - 25 ppm
0.03 ppm
57mV/decade ± 5mV

ION SELECTIVE BENEFITS

  • Stable reference for accurate and repeatable measurements
  • Fast response times
  • Favourable price/performance ratio

 

IJ-Cl
Chloride Combination Ion Selective Electrode
Body: Polypropylene, PEEK
Parameter: Cl-, Ag+
Reference: Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte
Temp Range: 0°C - 60°C
pH Range: 2 - 12
Measuring Range: 1.8 - 35000 ppm
Interfering Ions: I-, CN-, Br-, SCN-
Applications: Suitable for both the direct determination of Chloride and Silver, as well as an indicator in argentometric titration.
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard

BACK TO TOP

 

 

IJ-CN
Cyanide Combination Ion Selective Electrode
Body: Polypropylene, PEEK
Parameter: CN-
Reference: Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte
Temp Range: 0°C - 60°C
pH Range: 9 - 14
Measuring Range: 0.05 - 25 ppm
Interfering Ions: I-, Br-, S2-
Applications: Suitable for the direct determination of Cyanide ions in alkaline conditions. If the concentration of CN- > 10ppm, dilution before measurement is recommended.
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard

BACK TO TOP

 

 

IJ-Br
Bromide Combination Ion Selective Electrode
Body: Polypropylene, PEEK
Parameter: Br-
Reference: Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte
Temp Range: 0°C - 60°C
pH Range: 2 - 12
Measuring Range: 0.8 - 80000 ppm
Interfering Ions: I-, S2-, CN-, SCN-
Applications: Suitable for the direct determination of Bromide ions, as well as an indicator in argentometric titration.
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard

BACK TO TOP

 

 

IJ-I
Iodide Combination Ion Selective Electrode
Body: Polypropylene, PEEK
Parameter: I-
Reference: Double Junction Ag/AgCl/Sat KCl Gel with replaceable electrolyte
Temp Range: 0°C - 60°C
pH Range: 2 - 12
Interfering Ions: CN-, Hg2+, Br-, SCN-
Measuring Range: 0.13 - 130000 ppm
Applications: Suitable for the direct determination of Iodide ions, as well as an indicator in argentometric titration.
Cable Length: 1m. Standard (Max. 20m)
Connector: BNC Standard