IJ SERIES
Intermediate Junction Electrodes

Ionode's IJ Series addresses the common problem of contamination and clogging of the reference junction which can affect lesser electrodes. The unique design assures trouble-free and reliable measurements in samples as diverse as waste water, wine, cheese and mineral leachates.

 
 

Model Parameter Measuring Range Sensor Type Temperature Compensation
IJ14 Reference
Reference
n/a
IJ44A pH pH 0 - 12
A glass spear
Optional
IJ44C pH pH 0 - 14
C glass spear
Optional
IJ64 ORP ±2000mV
Platinum Wire
Optional
IJAg Ag+,Cl- ±2000mV
Silver Billet
n/a
IJAu ORP ±2000mV
Gold Wire
n/a

IJ SERIES BENEFITS

  • Superior performance in challenging samples
  • Easy access for cleaning
  • Renewable Junction overcomes contamination
  • Tris compatible...perfect for Life Science
  • User selectable reference electrolyte
  • Temperature compensated models
  • Suitable for measurements down to 0.25ml

 

IJ SERIES DIMENSIONS

NOTE: All IJ Series electrodes have identical dimensions

 

IJ 14
Intermediate Junction Reference Electrode
Body: Polypropylene
Temp Range: 0 - 60oC
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Note: Suitable Reference electrode for S Series and IH31

Back To Top

 

 

IJ 44A
Intermediate Junction pH Electrode
Body: Polypropylene
Temp Range: 0 - 60oC
pH Range: 0 - 12 pH
pH Sensor: A Glass Spear
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Slope: >97%
Zero pH: 7.0 ± 0.5
Cable Length: 1m. Standard (Max. 20m)

Back To Top

 

 

IJ 44C
Intermediate Junction pH Electrode for Alkaline Environments
Body: Polypropylene
Temp Range: 0 - 60oC
pH Sensor: C Glass Spear
pH Range: 0 - 14 pH
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Slope: >97%
Zero pH: 7.0 ± 0.5
Cable Length: 1m. Standard (Max. 20m)

Back To Top

 

 

IJ 64
Intermediate Junction ORP Electrode
Body: Polypropylene
Temp Range: 0 - 60oC
ORP Sensor: Platinum
ORP Range: ±2000mV
Reference: Double Junction Ag/AgCl/Sat KCl Gel
Cable Length: 1m. Standard (Max. 20m)
Note: General purpose ORP electrode

Back To Top

 

 

IJ Ag
Intermediate Junction Silver Billet Electrode
Body: Polypropylene
Temp Range: 0 - 60oC
Sensor: Silver
Range: ±2000mV
Reference: Double Junction Ag/AgCl/User Selectable Electrolyte
Cable Length: 1m. Standard (Max. 20m)
Note: For argentimetric titration using silver nitrate or similar

Back To Top

 

 

IJ Au
Intermediate Junction Gold ORP Electrode
Body: Polypropylene
Temp Range: 0 - 60oC
Sensor: Gold
Range: ±2000mV
Reference: Double Junction Ag/AgCl/Sat KCl gel
Cable Length: 1m. Standard (Max. 20m)
Note: ORP measurements in cyanide solutions